Invisible Precision: Optimizing Thermoplastic Masks for Artifact-Free Imaging in IGRT

Introduction: In IGRT, Precision Must Be Seen—Not Just Achieved

In the era of Image-Guided Radiotherapy (IGRT), patient immobilization is no longer evaluated solely by how accurately it restricts motion. It must also be imaging-transparent.

A thermoplastic mask that fits perfectly but introduces imaging artifacts can compromise target delineation, distort anatomy, and ultimately affect treatment accuracy. As imaging becomes central to treatment planning, verification, and adaptation, immobilization devices must support not only mechanical precision—but visual clarity.


The Problem of “Artifacts” in Imaging

Why Do Some Thermoplastic Masks Create CT Artifacts?

CT artifacts—such as streaking, shading, or localized distortion—often originate from inhomogeneous or contaminated materials within the imaging field.

Common causes include:

  • High-density fillers or impurities
  • Non-uniform polymer composition
  • Embedded additives with elevated atomic numbers

When X-rays pass through these materials, differential attenuation leads to beam hardening and reconstruction errors, appearing as streak artifacts in CT images.


The Role of High-Z Impurities and HU Distortion

Materials containing high atomic number (high-Z) elements disproportionately attenuate low-energy photons, artificially elevating measured Hounsfield Unit (HU) values.

This can result in:

  • Incorrect tissue density representation
  • Errors in electron density mapping
  • Dose calculation inaccuracies in treatment planning systems

Even small deviations in HU values can be clinically significant in high-precision treatments such as IMRT, VMAT, SBRT, and SRS.


The Solution: Material Purity and Intelligent Design

Medical-Grade Polymer Purity

High-quality thermoplastic masks are manufactured from medical-grade, high-purity polymers, carefully formulated to ensure:

  • Homogeneous composition
  • Consistent radiological properties
  • Predictable attenuation behavior

By eliminating unnecessary fillers and high-Z contaminants, these materials achieve low X-ray attenuation and near-tissue-equivalent imaging characteristics.

The result is a mask that becomes virtually “invisible” on CT—supporting accurate contouring and dose calculation.


MRI Compatibility: Designing for the MR-Linac Era

Why Non-Metallic, Non-Magnetic Materials Matter

With the increasing adoption of MR-Linac systems, immobilization devices must meet stringent MRI compatibility requirements.

Key design considerations include:

  • Zero metallic components
  • Non-magnetic, RF-safe polymers
  • Minimal magnetic susceptibility differences

Materials that fail to meet these criteria can cause:

  • Image distortion
  • Signal loss
  • Safety risks in high magnetic fields

MRI-compatible thermoplastic masks enable high-resolution soft-tissue visualization without compromising patient safety or image fidelity.


Dosimetric Impact: Small Attenuation, Big Consequences

Why Sub-Percent Attenuation Matters

From a dosimetric perspective, immobilization devices are part of the beam path. Even modest attenuation can introduce uncertainty.

High-quality thermoplastic masks are engineered to limit beam attenuation to well below 1%, ensuring:

  • Accurate dose modeling
  • Consistent beam delivery
  • Reliable comparison between planned and delivered dose

This is particularly critical in adaptive workflows, where daily imaging and dose recalculation rely on stable, predictable system behavior.


Supporting Adaptive Radiotherapy (ART)

Adaptive Radiotherapy demands:

  • Reproducible positioning
  • Artifact-free imaging
  • Reliable dose calculation

Immobilization materials that distort imaging or introduce dosimetric uncertainty undermine the very foundation of adaptation. Selecting imaging-compatible thermoplastic masks ensures that anatomical changes—not device artifacts—drive clinical decisions.


Conclusion: True Precision Is Invisible

In modern radiotherapy, the best immobilization solution is one that does its job without being seen.

By choosing thermoplastic masks that offer:

  • High material purity
  • CT and MRI compatibility
  • Minimal dosimetric impact

clinics lay the groundwork for accurate IGRT, confident adaptive planning, and future-ready treatment workflows.

Invisible precision is not optional—it is essential.

  • kevin clarke

    Product R&D Engineer | Radiotherapy Immobilization Specialist • Current Role: Product R&D at Guangzhou Maidfirm Medical Equipment Co., Ltd. • Expertise: Radiotherapy auxiliary equipment, thermoplastic materials, and manufacturing process optimization. • The Edge: Extensive frontline experience collaborating with top-tier manufacturers to turn complex R&D blueprints into high-precision medical tools. • Mission: Improving patient outcomes through better design and flawless execution.

    Related Articles

    Why Aging Thermoplastics Behave Unpredictably:

    A Polymer Science Perspective Introduction: When Consistency Slowly Disappears In daily radiotherapy practice, thermoplastic masks are expected to behave in a highly predictable manner—softening at a known temperature, molding smoothly,…

    HU Stability and Dose Accuracy:

    The Hidden Role of Immobilization Materials Introduction: When Small HU Errors Matter In modern radiotherapy, treatment accuracy depends not only on beam delivery systems and planning algorithms, but also on…

    One thought on “Invisible Precision: Optimizing Thermoplastic Masks for Artifact-Free Imaging in IGRT

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    You missed it

    Enhancing Setup Reproducibility in Head & Neck Radiotherapy:

    Enhancing Setup Reproducibility in Head & Neck Radiotherapy:

    Gentle Precision: Balancing Patient Comfort and Setup Rigidity in Pediatric Radiotherapy

    Gentle Precision: Balancing Patient Comfort and Setup Rigidity in Pediatric Radiotherapy

    Protecting OARs in Complex Head & Neck Treatments: Advanced Immobilization Strategies

    Protecting OARs in Complex Head & Neck Treatments: Advanced Immobilization Strategies

    Supine vs. Prone Positioning for Breast Cancer: Choosing the Right Auxiliary System for Your Clinic

    Supine vs. Prone Positioning for Breast Cancer: Choosing the Right Auxiliary System for Your Clinic

    Reducing Heart and Lung Exposure: Innovative Positioning Solutions in Left-Sided Breast Radiotherapy

    Reducing Heart and Lung Exposure: Innovative Positioning Solutions in Left-Sided Breast Radiotherapy

    Managing Respiratory Motion in Abdominal SBRT: Best Practices for High-Precision Positioning

    Managing Respiratory Motion in Abdominal SBRT: Best Practices for High-Precision Positioning